MARINE. CN-200 Copper Nickel Pipe Fittings
General Information
Fitting Size
(PXX)
Qualified
Wall
Thickness
Insertion
Depth Pre-
Install, A
Insertion
Depth Post-
Install, B
Outside
Diameter, C
Inside
Diameter, D
Minimum
Straight Run
Before a
Bend, E
1/2″ OD (T08) Class 200/700 1,29 0,95 0,84 0,51 1,50
1/4″ (P04) Class 200/700 1,29 0,95 0,84 0,55 1,50
3/8″ (P06) Class 200/700 1,40 1,04 1,05 0,69 1,63
1/2″ (P08) Class 200/700 1,61 1,18 1,26 0,85 1,75
3/4″ (P12) Class 200/700 1,86 1,36 1,49 1,06 2,00
1″ (P16) Class 200/700 2,16 1,57 1,80 1,33 2,38
1 1/4″ (P20) Class 200/700 2,59 1,88 2,10 1,67 2,88
1 1/2″ (P24) Class 200/700 2,98 2,16 2,49 1,91 3,25
2″ (P32) Class 200/700 3,27 2,37 3,12 2,39 4,00
 

1. All dimensions in inches.

 

2. Dimensions A, B, C, D & E are applicable to other fittings of the same size within this catalog.

 

3. For use on copper-nickel pipe per MIL-T-16420 (class 200, 90/10) or copper pipe per MIL-T-24107 (0.065″ wall).

 

4. For tooling dimensions refer to appropriate catalog.

 

5. Coupling “thru-bore” design permits pipe to pass completely through. All other fittings have an internal pipe stop.

 

6. Material per MIL-T-16420, Alloy 70600

 

7. LOKRING CN-200 Pipe fittings are rated at 250 psi from -60ºF to 425ºF

 

8. NAVSEA, ABS, LLOYD’S, USCG

 

9. Fire approved per NAVSEA, ABS and CFR 46 regulations

 

10. Other part configurations than those shown and custom configurations may be available,
contact Lokring™ for details

 

11. All dimensions are reference only and subject to change

 

 

WordPress Appliance - Powered by TurnKey Linux